By Nick Gromicko
Home Maintenance
Facts and Figures

Carbon Monoxide (CO) is a colorless, odorless, poisonous gas that forms from incomplete combustion of fuels, such as natural or liquefied petroleum gas, oil, wood or coal.
When CO is inhaled, it displaces the oxygen that would ordinarily bind with hemoglobin, a process the effectively suffocates the body. CO can poison slowly over a period of several hours, even in low concentrations. Sensitive organs, such as the brain, heart and lungs, suffer the most from a lack of oxygen.
High concentrations of carbon monoxide can kill in less than five minutes. At low concentrations, it will require a longer period of time to affect the body. Exceeding the EPA concentration of 9 parts per million (ppm) for more than eight hours may have adverse health affects. The limit of CO exposure for healthy workers, as prescribed by the U.S. Occupational Health and Safety Administration, is 50 ppm.
Any fuel-burning appliances which are malfunctioning or improperly installed can be a source of CO, such as:
| PPM | % CO in air | Health Effects in Healthy Adults | Source/Comments |
|---|---|---|---|
| 0 | 0% | no effects; this is the normal level in a properly operating heating appliance | |
| 35 | 0.0035% | maximum allowable workplace exposure limit for an eight-hour work shift | The National Institute for Occupational Safety and Health (NIOSH) |
| 50 | 0.005% | maximum allowable workplace exposure limit for an eight-hour work shift | OSHA |
| 100 | 0.01% | slight headache, fatigue, shortness of breath, errors in judgment | |
| 125 | 0.0125% | workplace alarm must sound (OSHA) | |
| 200 | 0.02% | headache, fatigue, nausea, dizziness | |
| 400 | 0.04% | severe headache, fatigue, nausea, dizziness, confusion; can be life-threatening after three hours of exposure | evacuate area immediately |
| 800 | 0.08% | convulsions, loss of consciousness; death within three hours | evacuate area immediately |
| 12,000 | 1.2% | nearly instant death |
PPM = parts per million of carbon monoxide in air.
CO detectors can monitor exposure levels, but do not place them:
Do place CO detectors:
In North America, some national, state and local municipalities require installation of CO detectors in new and existing homes, as well as commercial businesses, among them: Illinois, Massachusetts, Minnesota, New Jersey, Vermont and New York City, and the Canadian province of Ontario. Installers are encouraged to check with their local municipality to determine what specific requirements have been enacted in their jurisdiction.
Follow the manufacturer’s instructions, and cover sleeping areas at minimum. Placement guidance differs from smoke alarms, so read the packaging rather than assuming.
Yes. The sensors degrade, and most units carry a replacement date on the housing. An alarm past that date should be replaced rather than trusted.
Further reading: the CCPIA Standards of Practice.
Scheduling is easy, and we are here to help.